Disposable Endoscopic Linear Stapler and Reload Type B
Ergonomics Design
Antiskid coating
Optimized Lever Mechanics Technology
With four or five firings, the optimized lever mechanical design is adopted to make the operator fire more smoothly and easily.
Rotating Head Assembly
The rotating head can adjust three angles: 15°,30°,45°.
Stapling Protection
Protection design of 1.5 staples at
the front end of cutting line.
Intergrated Machining Anvil To ensure firm tissue stapling. The thin anvil can also be a non-invasive grasping forcep. |
Gecko-Claw Technology To ensure that staples can enter into the groove safely and accuratedly during clamping and firing. |
Droplet Groove Design Oriented and contact area increased by 30% to ensure better staple formation. |
Curved Tip Anvil Provides visibility and maneuver- ability around target tissues and vessels. |
A disposable endoscopic cutting stapler is a surgical instrument used in laparoscopic and endoscopic procedures to cut and staple tissue. It is designed to be used for a single procedure and then disposed of, reducing the risk of infection and eliminating the need for reprocessing and sterilization.The disposable endoscopic cutting stapler consists of a handle, shaft, and a cutting/stapling mechanism. The handle is used to control the opening and closing of the stapler to engage the tissue. The shaft is a long, thin tube through which the stapler is inserted into the body through a small incision or natural body opening. The cutting/stapling mechanism is located at the tip of the stapler shaft and is responsible for both cutting the tissue and applying the staples to secure the incision.During a procedure, the surgeon positions the stapler around the tissue to be cut and stapled, making sure the tissue is properly aligned within the jaws of the stapler. The surgeon then activates the stapler, which simultaneously cuts the tissue and places rows of staples on either side of the incision. This helps to control bleeding and secure the tissue together.Disposable endoscopic cutting staplers are available in various sizes and configurations to accommodate different tissue types and procedure requirements. It is important to use the appropriate size and type of stapler for each specific application to ensure optimal results.As with any surgical instrument, proper training and adherence to manufacturer guidelines are essential for safe and effective use of disposable endoscopic cutting staplers. It is recommended to consult with a healthcare professional or surgeon for specific information and instruction regarding the use of this device in medical procedures.
DISPOSABLE CARTRIDGE
Product code |
Description |
Staple Length |
open staple height |
closed staple height |
Type |
WLHZ-B-white |
GEN II, 2.5mm |
30mm,45mm,60mm |
2.5mm |
1.0 mm |
Ariticulation |
WLHZ-B-blue |
GEN II, 3.5mm |
30mm,45mm,60mm |
3.5mm |
1.6mm |
Ariticulation |
WLHZ-B-gold |
GEN II, 4.1mm |
45mm,60mm |
4.1mm |
1.8mm |
Ariticulation |
WLHZ-B-green |
GEN II, 4.8mm |
45mm,60mm |
4.8mm |
2.15mm |
Ariticulation |
WLHZ-B-tan |
Variable height |
30mm,45mm,60mm |
2.0/2.5/3.0mm |
0.7-1.1mm |
Ariticulation |
WLHZ-B-pruple |
Variable height |
45mm,60mm |
3.0/3.5/4.0mm |
1.2-1.6mm |
Ariticulation |
WLHZ-B-black |
Variable height |
45mm,60mm |
4.0/4.5/5.0mm |
1.6-2.1mm |
Ariticulation |
WLHZ-B-white |
GEN II, 2.5mm, cruved tip |
30mm,45mm,60mm |
2.5mm |
1.0 mm |
Ariticulation |
WLHZ-B-tan |
Variable height, cruved tip |
30mm,45mm,60mm |
2.0/2.5/3.0mm |
0.7-1.1mm |
Ariticulation |
A disposable endoscopiccutting stapler and cartridge is a surgical instrument used in minimally invasive procedures to cut and staple tissue. It is specifically designed for use in endoscopic surgeries, which involve inserting a long, thin tube with a camera and surgical tools into the body through small incisions.The disposable endoscopic cutting stapler consists of two main components: the stapler and the cartridge. The stapler is the handheld device that controls the cutting and stapling actions, while the cartridge houses the staples and cutting blade.During the procedure, the surgeon places the stapler and cartridge through a trocar or port in the patient's body. Once the tissue is properly positioned within the stapler, the surgeon activates the device, which simultaneously cuts the tissue and applies the staples to secure the cut edges together.These staplers and cartridges are typically designed for single-use only, meaning they are disposed of after each procedure to minimize the risk of infection and ensure consistent performance. The disposable nature also eliminates the need for cleaning and sterilization, saving time and resources in the operating room.It is important to note that the selection and use of specific staplers and cartridges should be based on the surgeon's expertise and a proper understanding of surgical techniques. Following manufacturer instructions and receiving appropriate training is crucial to ensure safe and effective use of the disposable endoscopic cutting stapler and cartridge.
Building 3, No. 1, Street 16, Baiyang Street, Qiantang District, Hangzhou, China
Http//: www.wellmedhz.com
Email: vivianlu@wellmedhz.com; speny@wellmedhz.com
Tel./Whatsapp/Wechat: 0086 13777135855 0086 13336896428